ATMOS GS 40 40 kW wood gasification boiler

by Atmos
SKU 01.05.40
Original price 5.362,04 € - Original price 5.362,04 €
Original price
5.362,04 €
5.362,04 € - 5.362,04 €
Current price 5.362,04 €
Energieeffizienz A+
Availability:
In stock

The Atmos GS 40 is a hand-fed wood gasification boiler for logs with a nominal output of 40 kW and a large combustion chamber for applications with higher heat demand. The model is designed for water-based heating systems and combines classic wood heating technology with an exhaust fan, ceramic combustion chamber, and buffer tank connection.

Wichtigste Vorteile

40 kW rated output for heating systems with higher heat demand

Hand-fed wood gasification boiler for logs up to 530 mm

Designed for operation in water-based systems with buffer storage tank

Fachhandel für Heiztechnik

  • Technische Beratung für Heiztechnik & Systemkomponenten
  • Sichere Zahlung
  • Paket- oder Speditionsversand je nach Produktart

GPSR Information

Name: Jaroslav Cankař a syn ATMOS

Address: elenského 487 294 21 Bělá pod Bezdězem, Cr

Email: info@atmos-zentrallager.de

Website: https://www.atmos.eu/de/

European Manufacturer: Yes

Product Overview & Application

The Atmos GS 40 wood gasification boiler is a manually fed hot water heating boiler designed for burning split logs and is intended for heating single-family homes and similar properties. With a nominal output of 40 kW, this model is aimed at applications with higher heat demand where a classic log wood boiler with wood gasification technology, a large fuel chamber, and clear, robust engineering is required.

Technology & Features

The boiler operates on the principle of downdraft gasification with an induced draft fan. The combustion air is preheated before being introduced into the combustion chamber, the secondary combustion chamber is equipped with ceramic components, and the boiler has an integrated cooling coil for overheat protection. Features include a thermometer, flue gas thermostat, boiler thermostat for the fan, and mechanical operation of the start-up damper.

Everyday Benefits

For practical operation, the Atmos GS 40 offers a large fuel shaft for logs up to 530 mm in length. This supports longer burn intervals and reduces the frequency of refueling compared to smaller units. The induced draft fan contributes to more even combustion, while the clear electromechanical control logic makes the boiler appealing to users who prefer robust and straightforward technology.

System Integration & Compatibility

The boiler is designed for integration into water-based heating systems. According to the documentation, installation with a buffer tank is mandatory; for the GS 40, the technical specifications state a minimum volume of 750 liters. When used with buffer tanks, benefits include more economical operation, lower fuel consumption, and compatibility with radiators and underfloor heating. For return temperature protection, integration via a Laddomat 22 or a suitable thermostatic control valve is recommended.

Technical Specifications at a Glance

A compact overview of the most important, reliably verified core data for the Atmos GS 40.

Nominal Output 40 kW
Fuel Wood
Combustion Technology Wood Gasification
Efficiency 88.8 %
Energy Efficiency Class A+
Max. Flow Temperature 80 - 90 °C
Max. Operating Pressure 2.5 bar
Log Length 530 mm
Boiler Class 5
Draft Requirement 25 Pa
Flue Gas Temperature 250 °C
Flue Pipe Connection 150/152 mm
Height 1410 mm
Width 680 mm
Depth 1045 mm
Power Consumption 39 W
Connection Type 230 V / 50 Hz

Installation

Installation must be carried out in a suitable boiler or heating room with a guaranteed supply of combustion air; installation in living spaces is not permitted. A concrete or metal foundation is recommended. The electrical connection must be hardwired at 230 V / 50 Hz, not via a Schuko plug. The chimney, flue gas pipe, and hydraulic connection must be compatible with the system and professionally executed.

Notes

The boiler is designed for dry split or chopped wood with a residual moisture content of approximately 12 to 20%; the documentation recommends wood that has been stored for at least two years. The prescribed minimum return temperature is 65 °C. During normal operation, the flue gas temperature should not fall below 110 °C. The documentation also explicitly emphasizes the need for professional commissioning and user instruction.

Scope of Delivery

  • Atmos GS 40 wood gasification boiler
  • one steel brush with accessories
  • one poker
  • one fill valve
  • the operating and maintenance manual
  • one HONEYWELL FR 124 draft regulator
  • one ash pan.
HerstellerAtmos
ProdukttypWood gasification boiler
ModellGS 40
MPN / Herstellernummer01.05.40
GTIN / EAN8595183306138
Förderstatusnot eligible for funding
Nennleistung40.0 kW
BrennstoffHolz
VerbrennungstechnikWood gasifier
Wirkungsgrad86.4 %
EnergieeffizienzklasseA+
Max. Vorlauftemperatur65.0 °C
Max. Betriebsdruck2.5 bar
Max. Scheitholzlänge530 mm
KesselklasseClass 5
Zugbedarf25 Pa
Abgastemperatur251 °C
Rauchrohranschluss150 mm
Empfohlenes Puffervolumen2500 l
Höhe1434 mm
Breite959 mm
Tiefe678 mm

Zu diesem Produkt wurden noch keine sauber darstellbaren produktspezifischen Fragen hinterlegt. Unser Fachteam unterstützt dich gerne bei technischen Fragen zur Auswahl, Montage oder Kompatibilität.

GPSR Information

Name: Jaroslav Cankař a syn ATMOS

Address: elenského 487 294 21 Bělá pod Bezdězem, Cr

Email: info@atmos-zentrallager.de

Website: https://www.atmos.eu/de/

European Manufacturer: Yes

Compare products

{"one"=>"Select 2 or 3 items to compare", "other"=>"{{ count }} of 3 items selected"}

Select first item to compare

Select second item to compare

Select third item to compare

Compare